In the present work, accelerated method is
used for the measurement of iodine value, wherein
mercuric acetate is directly used in the powder form.
The method only requires to add the catalyst mercuric
acetate in the process of determination without changing
the operational steps of the Wijs method. Compared
with the Wijs method in which it will take at least 30
minutes to finish it, the rapid determination method can
make the determination reaction finished in 3 minutes.
The iodine value of different vegetable oils such as
Kacchighani mustard oil (Kgmu, Dalda),Kacchighani
mustard oil (Kgmu1,Mahakosh), Kacchighani mustard
oil (Kgmu2,Tez),premium mustard oil kacchighaani
(Pmukg, RRO Mustdil), Kacchighani mustard oil
(Kgmu3,Nature fresh) and Kacchighani mustard oil
(Kgmu4, Engine)oils were determined by regular Wijs
method for 30 minutes whereas when we apply catalytic
Wijs method with use of 2 mg, 5 mg and 10 mg of
mercuric acetate to perform as catalyst then it is
reducing the time of analysis to 3 minutes. When catalyst
is used the different values obtained for standard
deviations are 0.14 for 2mg, 0.27for 5mg and 0.3 for 10
mg whereas 0.35 for non catalyst addition. The results
obtained in this present work aremore % difference in
IV of pure kacchighani mustard oil (Pkgmu)and
Kacchighani mustard oil (Kgmu2).