Application of cyclone technology has been
implemented in cement production since the
construction because it is simple, low cost, reliability and
stability both in high pressure environment and high
temperature (900 oC). The ideal solution to improve the
burning process is by optimizing the cyclone heat
exchanger. The aim of this study is to see the effect of
baffle plate for outlet duct to the outlet gas flow
distribution in cyclone preheater CN1–A and CN1–B.
Computational Fluid Dynamics is used for modelling the
swirl turbulent flow inside the cyclone. The simulation
shows It was found that by adding baffle plate (width
between 250–300 mm) able to maximize the gas flow
distribution and also improve the heat transfer and
potentially to reduce the loss from heat loss by 0.9–1.3%
(equivalent 588 – 722 billion Rupiah/year). Baffle plate
also caused pressure drop in multicyclone system)
Keywords : Computational Fluid Dynamics, Efficiency, Cyclone Geometry, Pressure Drop, Dust Loss, Thermal Loss